Vores kunder ligger øverst på Google

Google Ads Specialister fra Vestjylland

Vi er 100% dedikerede til Google Annoncering – Vi har mange års erfaring med Google Ads og den bruger vi på at opsætte, optimere & vedligeholde vores fantastiske kunders konti.

100% Specialiseret i Google Ads
Vi har mange års erfaring fra +300 konti
Ingen lange bindinger & evighedskontrakter
Jævnlig opfølgning med hver enkelt kunde
Vi tager din virksomhed seriøst

46 results (0,15530 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Haes AlarmSense 2 Zone Control Panel ALS-2

Haes AlarmSense 2 Zone Control Panel ALS-2

Haes AlarmSense 2 Zone Control Panel ALS-2Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The AlarmSense encompasses all of these attributes to provide a panel that meets a variety of needs. For the fire alarm engineer the AlarmSense has been designed to minimise labour costs. There is ample room for wiring changing batteries and clear indication. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system. Simplicity was one of the most important aspects when considering the end user of a fire alarm panel.The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. Two or four AlarmSense fire zone circuits are provided plus two additional conventional monitored sounder circuits. Fire Fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included. Haes AlarmSense panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 or 4 AlarmSense zonesApproved to EN54-2 4Smart design easy to install commission maintainFalse alarm reduction with non priority signallingLocal general alarm switchingClass change pulsing inputsIdeal for HMOsFire fault relaysOne man walk testKey-switch or code entry for activation of controlsFault diagnostics mode

GBP 200.12
1

Haes AlarmSense 4 Zone Control Panel ALS-4

Haes AlarmSense 4 Zone Control Panel ALS-4

Haes AlarmSense 4 Zone Control Panel ALS-4Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The AlarmSense encompasses all of these attributes to provide a panel that meets a variety of needs. For the fire alarm engineer the AlarmSense has been designed to minimise labour costs. There is ample room for wiring changing batteries and clear indication. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system. Simplicity was one of the most important aspects when considering the end user of a fire alarm panel.The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. Two or four AlarmSense fire zone circuits are provided plus two additional conventional monitored sounder circuits. Fire Fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included. Haes AlarmSense panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 or 4 AlarmSense zonesApproved to EN54-2 4Smart design easy to install commission maintainFalse alarm reduction with non priority signallingLocal general alarm switchingClass change pulsing inputsIdeal for HMOsFire fault relaysOne man walk testKey-switch or code entry for activation of controlsFault diagnostics mode

GBP 223.67
1

Haes AlarmSense Plus 8 Zone Control Panel ASP-8

Haes AlarmSense Plus 8 Zone Control Panel ASP-8

Haes AlarmSense Plus 8 Zone Control Panel ASP-8Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes AlarmSense PLUS encompasses all of these attributes to provide the fire alarm engineers panel of choice. For the fire alarm engineer the AlarmSense PLUS has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system.Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. All inputs and outputs are fully programmable and there are options to have delays and coincidence attributes to the outputs.As standard all AlarmSense PLUS panels provide two additional conventional monitored sounder circuits Fire Fault VFCO relays Fire Fault switched negative outputs class change and an alert input. Haes AlarmSense PLUS panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 AlarmSense zonesApproved to EN54-2 4False alarm reduction with non priority signallingLocal general alarm switchingClass change pulsing programmable inputsIdeal for HMOsProgrammable relays outputsModular expansion zone cardsOne man walk testsKey-switch or code entry for activation of controlsFully functional repeater panels

GBP 372.60
1

Haes AlarmSense Plus 4 Zone Control Panel ASP-4

Haes AlarmSense Plus 4 Zone Control Panel ASP-4

Haes AlarmSense Plus 4 Zone Control Panel ASP-4Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes AlarmSense PLUS encompasses all of these attributes to provide the fire alarm engineers panel of choice. For the fire alarm engineer the AlarmSense PLUS has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system.Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. All inputs and outputs are fully programmable and there are options to have delays and coincidence attributes to the outputs.As standard all AlarmSense PLUS panels provide two additional conventional monitored sounder circuits Fire Fault VFCO relays Fire Fault switched negative outputs class change and an alert input. Haes AlarmSense PLUS panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 AlarmSense zonesApproved to EN54-2 4False alarm reduction with non priority signallingLocal general alarm switchingClass change pulsing programmable inputsIdeal for HMOsProgrammable relays outputsModular expansion zone cardsOne man walk testsKey-switch or code entry for activation of controlsFully functional repeater panels

GBP 343.44
1

Rutland ETS.18314.PVD Responder 24 Electromagnetic Door Closer

Rutland ETS.18314.AB Responder 24 Electromagnetic Door Closer

Rutland ETS.18314.SNP Responder 24 Electromagnetic Door Closer

Haes 2 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-2

Haes 2 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-2

Haes 2 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-2Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes Excel-EN encompasses all of these attributes to provide the fire alarm engineers panel of choice. The Excel-EN combines the benefits of addressable panels with the simplicity of conventional panels for the fire alarm engineer the Excel-EN has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries.Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system. Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system.All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features of the Excel- EN also include 3 different modes to help reduce false alarms. Local fire authorities are demanding this type of functionality to reduce unwanted callouts from alarm receiving centres as standard all Excel-EN panels provide two monitored sounder circuits Fire Fault VFCO relays and Fire Fault switched negative outputs class change and an alert input. Excel-EN panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 zones3 modes to manage false alarmsIndividually selectable Twin Wire zonesApproved to EN54-2 43 year warrantyClass change alert programmable inputsProgrammable relays outputsModular expansion zone cards including additional sounder circuitsOne man walk testKey-switch or code entry for activation of controlsFully functional repeater panelsTwo monitored sounder circuits fitted as standard.

GBP 294.74
1

Haes Eclipse 2 Zone Conventional Twin Wire Control Panel ECL-2

Haes Eclipse 2 Zone Conventional Twin Wire Control Panel ECL-2

Haes Eclipse 2 Zone Conventional Twin Wire Control Panel ECL-2Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. As the entry level panel from Haes the Eclipse encompasses all of these attributes to provide a panel that meets a variety of needs. For the fire alarm engineer the Eclipse has been designed to minimise labour costs. There is ample room for wiring changing batteries and clear indication. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system.Simplicity was one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. The Eclipse is the only entry level panel on the market that will reduce false alarms. The Eclipse can be programmed so that it requires a secondary confirmation before sending the panel into alarm. Fire and Rescue services are looking to this type of functionality to allow them to respond to Alarm Receiving Centres.Two or four fire zone circuits are provided plus two monitored sounder circuits. Fire Fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included. The fire zone outputs can be set as Twin Wire by DIL switch selection. In Twin Wire configuration special detector bases and call points must be used. Eclipse panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 or 4 zoneFalse alarm management modeTwin Wire selection by DIL switchApproved to EN54-2 4Smart design easy to install commission serviceClass change inputs pulsing inputsFire fault relays2 monitored sounder circuitsOne man walk testKey-switch or code entry for activation of controlsNon latching zone for interfacingFault diagnostics mode

GBP 194.92
1

Haes 6 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-6

Haes 6 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-6

Haes 6 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-6Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes Excel-EN encompasses all of these attributes to provide the fire alarm engineers panel of choice. The Excel-EN combines the benefits of addressable panels with the simplicity of conventional panels for the fire alarm engineer the Excel-EN has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries.Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system. Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system.All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features of the Excel- EN also include 3 different modes to help reduce false alarms. Local fire authorities are demanding this type of functionality to reduce unwanted callouts from alarm receiving centres as standard all Excel-EN panels provide two monitored sounder circuits Fire Fault VFCO relays and Fire Fault switched negative outputs class change and an alert input. Excel-EN panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 zones3 modes to manage false alarmsIndividually selectable Twin Wire zonesApproved to EN54-2 43 year warrantyClass change alert programmable inputsProgrammable relays outputsModular expansion zone cards including additional sounder circuitsOne man walk testKey-switch or code entry for activation of controlsFully functional repeater panelsTwo monitored sounder circuits fitted as standard.

GBP 370.74
1

Haes 4 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-4

Haes 4 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-4

Haes 4 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-4Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes Excel-EN encompasses all of these attributes to provide the fire alarm engineers panel of choice. The Excel-EN combines the benefits of addressable panels with the simplicity of conventional panels for the fire alarm engineer the Excel-EN has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries.Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system. Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system.All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features of the Excel- EN also include 3 different modes to help reduce false alarms. Local fire authorities are demanding this type of functionality to reduce unwanted callouts from alarm receiving centres as standard all Excel-EN panels provide two monitored sounder circuits Fire Fault VFCO relays and Fire Fault switched negative outputs class change and an alert input. Excel-EN panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 zones3 modes to manage false alarmsIndividually selectable Twin Wire zonesApproved to EN54-2 43 year warrantyClass change alert programmable inputsProgrammable relays outputsModular expansion zone cards including additional sounder circuitsOne man walk testKey-switch or code entry for activation of controlsFully functional repeater panelsTwo monitored sounder circuits fitted as standard.

GBP 317.90
1

Haes Eclipse 4 Zone Conventional Twin Wire Control Panel ECL-4

Haes Eclipse 4 Zone Conventional Twin Wire Control Panel ECL-4

Haes Eclipse 4 Zone Conventional Twin Wire Control Panel ECL-4Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. As the entry level panel from Haes the Eclipse encompasses all of these attributes to provide a panel that meets a variety of needs. For the fire alarm engineer the Eclipse has been designed to minimise labour costs. There is ample room for wiring changing batteries and clear indication. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system.Simplicity was one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. The Eclipse is the only entry level panel on the market that will reduce false alarms. The Eclipse can be programmed so that it requires a secondary confirmation before sending the panel into alarm. Fire and Rescue services are looking to this type of functionality to allow them to respond to Alarm Receiving Centres.Two or four fire zone circuits are provided plus two monitored sounder circuits. Fire Fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included. The fire zone outputs can be set as Twin Wire by DIL switch selection. In Twin Wire configuration special detector bases and call points must be used. Eclipse panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 or 4 zoneFalse alarm management modeTwin Wire selection by DIL switchApproved to EN54-2 4Smart design easy to install commission serviceClass change inputs pulsing inputsFire fault relays2 monitored sounder circuitsOne man walk testKey-switch or code entry for activation of controlsNon latching zone for interfacingFault diagnostics mode

GBP 223.67
1

Haes 8 Zone Excel-EN Conventional Twin Wire Control Panel with High Spec Zone Card XLEN-8

Haes 8 Zone Excel-EN Conventional Twin Wire Control Panel with High Spec Zone Card XLEN-8

Haes 8 Zone Excel-EN Conventional Twin Wire Control Panel with High Spec Zone Card XLEN-8Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes Excel-EN encompasses all of these attributes to provide the fire alarm engineers panel of choice. The Excel-EN combines the benefits of addressable panels with the simplicity of conventional panels for the fire alarm engineer the Excel-EN has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries.Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system. Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system.All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features of the Excel- EN also include 3 different modes to help reduce false alarms. Local fire authorities are demanding this type of functionality to reduce unwanted callouts from alarm receiving centres as standard all Excel-EN panels provide two monitored sounder circuits Fire Fault VFCO relays and Fire Fault switched negative outputs class change and an alert input. Excel-EN panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 zones3 modes to manage false alarmsIndividually selectable Twin Wire zonesApproved to EN54-2 43 year warrantyClass change alert programmable inputsProgrammable relays outputsModular expansion zone cards including additional sounder circuitsOne man walk testKey-switch or code entry for activation of controlsFully functional repeater panelsTwo monitored sounder circuits fitted as standard.Please Note As well as 4x monitored conventional twin wire zones the high spec zone card also offers 2x switched -ve outputs 1x aux relay output 2x monitored sounder circuits.

GBP 370.74
1

Ziton ZP1-F2-03 Conventional 2 Zone Fire Panel with User Interface

Ziton ZP1-F2-03 Conventional 2 Zone Fire Panel with User Interface

Ziton ZP1-F2-03 Conventional 2 Zone Fire Panel with User InterfaceThe ZP1-F2 is a conventional fire alarm control panel. It is supplied in local language with 2 zones that support up to 32 devices per zone as well as up to 2 supervised relay outputs dedicated to sounder control. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.ZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.Key FeaturesModern elegant designEasy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk testAuxiliary standard supervised relay output boardsNetworkable up to 64 zones

GBP 194.68
1

Kentec K1844-40 Sigma A-CP 4 Zone Control Panel 115V Grey

Kentec K1844-40 Sigma A-CP 4 Zone Control Panel 115V Grey

Kentec K1844-40 Sigma A-CP 4 Zone Control Panel 115V GreyThe Sigma A-CP is a range of conventional fire control panels with an optionalbuilt-in communicator.With two four or eight initiating circuits all panels can be extensivelyconfigured via a simple front panel operated programming method.The low standby power requirements and cost effective small batteries allowthe panel to be mounted in a discrete enclosure which is available in red orgrey.A simple programming method using just 3 front panel buttons allows anextensive list of configuration options to be set and reviewed.Single board construction enables easy removal of all electronic parts byremoving just two screws and ample provision of cable entry knockoutssimplify installation.4 Amp notification appliance power and built-in selectable sync protocolsprovide ample power and control for a wide range of standard notificationappliances.The built-in RS485 communications bus provides the facility to connect 4wire annunciators or ancillary relay boards to provide further indication andcontrol options throughout a premises.The optional DACT allows dual line reporting to central stations and providesa 500-event history buffer.Key Features4 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 431.34
1

Cooper CFVCSHFG VoCall Type B Surface Mount Green Outstation

Cooper CFVCSHF VoCall Type B Surface Mount Red Outstation

Cooper CFVCSHFSS VoCall Type B Surface Mount Stainless Steel Outstation

Kentec K1844-41 Sigma A-CP 4 Zone Control Panel 240V Grey

Kentec K1844-41 Sigma A-CP 4 Zone Control Panel 240V Grey

Kentec K1844-41 Sigma A-CP 4 Zone Control Panel 240V GreyThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features4 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 431.34
1

Zeta ID28 Infinity ID2 Intelligent 2 Wire 8 Zone Fire Panel

Zeta ID28 Infinity ID2 Intelligent 2 Wire 8 Zone Fire Panel

Zeta ID28 Infinity ID2 Intelligent 2 Wire 8 Zone Fire PanelZeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a 2 Wire installation less cable quicker installation cost savings on labourproduct and has the facility to I.D. the devices.The system is built on the proven communication protocol developed by Zeta Alarm Systems and shares the same platform as our largest most powerful system.The ID2 can be used for new installations as a retrofit for any conventional system or as a replacement for existing 2 wire systems when the extra features are deemed to be desirablenecessary. This is possible because the ID2 devices sit on radial circuits thus making it easy to upgrade a system with the facility to I.D. devices without the need to re-wire.Key Features The system meets the full requirements of BSEN5839 parts 1 and 6.The control panel has been designed to meet EN54 parts 2 and 4.Each device can be uniquely identified by the panelDevice Count VerificationAlarm Verification2048 Event HistoryID2 Smartphone App available for iOS and AndroidCable Break protectionCable Short Circuit ProtectionOne man walk test facilityAuto configuration for easy set upSafer than a traditional 2 wireconventional system as it tells you exactly where the event is - no time wasted searching a whole zonePlease note This product requires 2 xNP7-12 Batteries.

GBP 392.72
1

Kentec K1844-11 Sigma A-CP 4 Zone Control Panel 240V Red

Kentec K1844-11 Sigma A-CP 4 Zone Control Panel 240V Red

Kentec K1844-11 Sigma A-CP 4 Zone Control Panel 240V RedThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features4 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 431.34
1

Kentec K1844-10 Sigma A-CP 4 Zone Control Panel 115V Red

Kentec K1844-10 Sigma A-CP 4 Zone Control Panel 115V Red

Kentec K1844-10 Sigma A-CP 4 Zone Control Panel 115V RedThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features4 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 431.34
1

Cooper CF3000PRG Intelligent Addressable Touch Screen Repeater Panel DF6000PRG FX6000PR

Cooper CF3000PRG Intelligent Addressable Touch Screen Repeater Panel DF6000PRG FX6000PR

Cooper CF3000PRG Intelligent Addressable Touch Screen Repeater Panel DF6000PRG FX6000PRThe control panel has the ability to support complex cause and effect programming and a wide range of user controllable functions make the system ideal for a diverse range of projects from industrial applications through to large multi-site commercial developments.The ULCF3000 uses soft addressing to minimise installation time and remove the potential for error associated with manual addressing.Each of the system components have been specifically designed to operate as part of a ULCF3000 UL Listed system providing assurance that the panel the detectors the interfaces and the ancillaries are all fully compatible with each other and that the full range of system functionality is supported by each device.Key FeaturesTouchscreen Display2 or 4 Class A Style 7 SLC loopsEvent History Buffer 9999 events with DateTime stamp4 Notification appliance circuits NACs outputs3 programmable general purpose relaysDedicated alarm and trouble relaysShort circuit isolators incorporated into each loopUp to 200 addresses per loopFully monitored network cable up to 126 panelsOptional integral printerAlarm VerificationPAS Positive Alarm SequencPre-Signal per Point NFPA 70 72 compliantRemote Alarm NAC silenced Alarm Reset Trouble Supervisory and drill via addressable moduleBenefitsSupports a comprehensive range of soft addressing modules and devices for greater flexibility in designMenu driven graphical user interface for ease of operationReduced commissioning time through soft addressing and auto learn functionsProgramming and trouble-shooting time minimised by using a range of features such as auto config walk test system details analogue values etc

GBP 395.10
1

Scope RX2 Mk2 Two Channel POCSAG Receiver with Logging Facilities

Ziton ZP1-F8-03 Conventional 8 Zone Fire Panel with User Interface

Ziton ZP1-F8-03 Conventional 8 Zone Fire Panel with User Interface

Ziton ZP1-F8-03 Conventional 8 Zone Fire Panel with User InterfaceZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The ZP1-F8 is a conventional fire alarm control panel. It is supplied in local language with 8 zones that support up to 32 devices per zone as well as up to 4 supervised relay outputs dedicated to sounder control and fire routing. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.The panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.Key FeaturesModern elegant designEasy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk testAuxiliary standard supervised relay output boardsNetworkable up to 64 zones

GBP 237.49
1